尹小小 发表于 2021-4-15 19:27:41

聚碳酸酯模拟

我做的是聚合反应模拟
->Processing input specifications ...

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      VAN KREVELEN PROPERTY ESTIMATION IS MISSING PARAMETER VALUES
      FOR GROUP NUMBER (161) IN SEGMENT T-BPA.
      THE ENTROPY OF FUSION HAS BEEN SET TO ZERO FOR THIS GROUP.

      THE GLASS TRANSITION FUNCTION HAS BEEN SET TO ZERO FOR THIS GROUP.

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      PARAMETER DCPLS/ELEMENT1 (DATA SET 1)
      LOWER BOUND VIOLATED FOR COMPONENT DPC
      VALUE = -0.23693E+16, LOWER BOUND = -0.10000E+10

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      PARAMETER CPIG (DATA SET 1) FOR COMPONENT B-DPC:
      UNREASONABLE HEAT CAPACITY CALCULATED AT TEMPERATURE UPPER BOUND,
      VALUE =0.20868E+09 J/KMOL-K.VALUE SHOULD BE LESS THAN
      MAXIMUM ALLOWABLE VALUE =0.24943E+08 J/KMOL-K.PLEASE CHECK
      YOUR INPUT FOR THE CPIG PARAMETERS.

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      NRTL BINARY PARAMETERS FOR ALL COMPONENT PAIRS ARE ZERO,
      YOUR RESULTS MAY NOT BE ACCURATE. PLEASE REVIEW AND PROVIDE BINARY
      PARAMETERS AS APPROPRIATE.

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      MARK-HOUWINK VISCOSITY MODEL HAS MISSING PARAMETERS:
      THE CRITICAL MOLECULAR WEIGHT (CRITMW) IS MISSING FOR COMPONENT PC
      AN APPROXIMATE VALUE OF30000 IS ASSUMED

Flowsheet Analysis :

COMPUTATION ORDER FOR THE FLOWSHEET:
EST PREPOLY1 PREPOLY2 PREPOLY3 EVA EVA-SEP PHOH-SEP

->Calculations begin ...


   Block: EST      Model: RCSTR

   Block: PREPOLY1 Model: RCSTR

   Block: PREPOLY2 Model: RCSTR

   Block: PREPOLY3 Model: RCSTR

   Block: EVA      Model: RPLUG
*** SEVERE ERROR
      FORTRAN INVALID OPERATION ENCOUNTERED.


   Block: EVA-SEPModel: SEP

   Block: PHOH-SEP Model: SEP

->Simulation calculations completed ...

这是控制面板上的提示,有两个警告,和一个模拟过程的严重警告,但是结果显示基本可用,有什么解决方案吗?

542925680 发表于 2021-4-15 19:27:41

交互作用参数缺失么?是不是数据库数据不全啊

45465496 发表于 2021-4-15 19:27:41

这个模拟解决了嘛
页: [1]
查看完整版本: 聚碳酸酯模拟