路灯接地电阻的检测方法
征能ES3010接地电阻仪(简易型)具有:2、3线法接地电阻、接地电压测量。手动换档,数据上传功能,报警功能,数据存储500组,接地电阻量程:0.00Ω~3000Ω,接地电压量程:0~600V等。此为测量路灯的其中一个实例。准备测量的路灯
http://m.znele.com/uploads/allimg/160111/1-1601111330445F.jpg
打开征能ES3010接地电阻仪(简易型)仪表箱,准备接线
http://m.znele.com/uploads/allimg/160111/1-160111133053426.jpg
按下图接线,红,黄,绿线,分别相差5米。此为精密三线法测量。
http://m.znele.com/uploads/allimg/160113/1-160113111642225.jpg
打接地棒,将红、黄测试线分别钳在接地棒上
http://m.znele.com/uploads/allimg/160111/1-1601111331132B.jpg
http://m.znele.com/uploads/allimg/160111/1-160111133123649.jpg
将绿色测试线钳在路灯接地引下线上
http://m.znele.com/uploads/allimg/160111/1-160111133132O5.jpg
测试线按对应颜色与主机接线
http://m.znele.com/uploads/allimg/160111/1-160111133142U8.jpg
接线完成,准备测试
http://m.znele.com/uploads/allimg/160111/1-160111133153O0.jpg
将旋转开关旋至30Ω档
http://m.znele.com/uploads/allimg/160111/1-160111133205564.jpg
按红色TEST键开始测试
http://m.znele.com/uploads/allimg/160111/1-1601111332141O.jpg
仪表测试10秒倒计时中
http://m.znele.com/uploads/allimg/160111/1-160111133224210.jpg
测出接地电阻值为6.04Ω,国家规定路灯10Ω以下。接地正常
http://m.znele.com/uploads/allimg/160111/1-160111133233962.jpg
测量完成,旋转开关旋至OFF档关机,收工
http://m.znele.com/uploads/allimg/160111/1-160111133242O9.jpg
以上是征能ES3010接地电阻仪(简易型)检测路灯接地电阻值的实例。
如需购买或了解更多此仪表的参数,请拔打:020-36544171,手机:13802775930,QQ:1437841048
{:1106_362:}