295610399 发表于 2015-6-26 21:20:56

ProII 双效蒸发的一个题,不收敛,求高手帮忙解决

某丙烯腈装置废水流率75148.1 kg/h,其中含有丙烯腈聚合物(以C6H8N2O计算)816 kg/h,温度113℃,压力600 kPa。要求通过蒸发把废水中的水份蒸出83%,冷凝后的净化水作为工艺循环水使用,使浓缩液中的丙烯腈聚合物浓度达到5.9%以上。多效蒸发器的最终压力不低于20 kPa,加热蒸汽压力为470 kPa饱和水蒸气。要求模拟双效蒸发器的操作。
下面是我做的inp文件。
TITLE
TOLERANCE STREAM =0.01,-0.555556,0.01,0.01, TEMPERATURE=-0.0555556, &
         PRESSURE=0.005, DUTY=0.001, MISCELLANEOUS=0.003, FLASH=3E-6
DIMENSION METRIC, TEMP=C, PRES=MPA, WT=KG, TIME=HR, LENGTH=M, &
         FLENGTH=MM, LIQVOL=M3, VAPVOL=M3, LDENSITY=KG/M3, &
         VDENSITY=KG/M3, XDENSITY=DENS, SPVOL=M3/KG-MOL, &
         SPVVOL=M3/KG-MOL, ENERGY=KCAL, WORK=KW, DUTY=KCAL/HR, &
         CONDUCT=KC/H, HTCOEF=KC/H, FOUL=HMC/K, VISCOSITY=CP, &
         KVIS=CST, SURFACE=D/CM, STDTEMP(C)=0, &
         STDPRES(KG/CM2)=1.0332, PBASIS(KG/CM2)=1.0332
SEQUENCE SIMSCI
CALCULATION TRIALS=20, RECYCLE=ALL, TVPBASIS=37.7778, &
         RVPBASIS=APIN, COMPCHECK=CALC, MAXOPS=1000000, CDATA=FIX, &
         FLASH=DEFAULT, DVARIABLE=ON
COMPONENT DATA
LIBID 1,H2O, BANK=SIMSCI,PROCESS
LIBID 2,BCYEET, BANK=SIMSCI
THERMODYNAMIC DATA
METHOD SYSTEM(VLLE)=UNIF, SET=UNIF01, DEFAULT
STREAM DATA
PROPERTY STREAM=S1, TEMPERATURE=113, PRESSURE=0.6, PHASE=M, &
         COMPOSITION(WT,KG/H)=1,74332.1/2,816
PROPERTY STREAM=S6, PRESSURE=0.47, PHASE=V, COMPOSITION(WT,KG/H)=1, &
      30000
UNIT OPERATIONS
HX   UID=E1
      HOTFEED=S6, M=S7
      COLD FEED=S5, M=S2
      CONFIGURE COUNTER
      OPER HLFRAC=1
FLASH UID=F1
      FEED S1,S2
      PRODUCTW=S3, V=S8
      ADIABATIC PRESSURE=0.0666
SPLITTER UID=SP1
      FEED S3
      PRODUCTM=S4, M=S5
      OPERATION OPTION=FILL
      SPEC STREAM=S5, RATE(KGM/H),TOTAL,WET, DIVIDE, STREAM=S3, &
               RATE(KGM/H),TOTAL,WET, VALUE=0.8
FLASH UID=F2
      FEED S4
      PRODUCTW=S10, V=S14
      ADIABATIC PRESSURE=0.02
CONTROLLER UID=CN1
      SPEC STREAM=S10, CONC(CMASS,KG/M3), COMP=2, VALUE=0.059
      VARY STREAM=S6, RATE(WT,KG/H)
      CPARAMETER IPRINT, CONTINUE, ITER=20
SPLITTER UID=SP2
      FEED S10
      PRODUCTM=S11, M=S12
      OPERATION OPTION=FILL
      SPEC STREAM=S11, RATE(KGM/H),TOTAL,WET, DIVIDE, STREAM=S10, &
               RATE(KGM/H),TOTAL,WET, VALUE=0.2
HX   UID=E2
      HOTFEED=S8, M=S9
      COLD FEED=S12, M=S13
      CONFIGURE COUNTER
      OPER HLFRAC=1
END

295610399 发表于 2015-6-26 21:20:56

求高手们解答

kill2000 发表于 2015-6-26 21:20:56

上源文件啊,这样,效率太低

295610399 发表于 2015-6-26 21:20:56

这是源文件。

295610399 发表于 2015-6-26 21:20:56

kill2000 发表于 2015-6-28 14:42
上源文件啊,这样,效率太低

已上传到。。。

benzene 发表于 2015-6-26 21:20:56

谢谢分享
页: [1]